Revision as of 01:52, 31 October 2025 by DGast (talk | contribs) (Created page with "== Version 5.3.5.2 ==  Download Version 5.3.5.2 #Implements the TDA204 digitizer for the T10. #Includes the self-extracting executable for train processor version 4.2.0.<br>    The executable is named P040200.EXE.<br>    Version PROC4.2.0 06/02/2025 #Added cmt-curl configurable consist and maintenance reporting via ftp or sftp.  This is intended to be a universal method for all our units in the future. #Added ZIPTRAI...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)

Version 5.3.5.2

 Download Version 5.3.5.2


  1. Implements the TDA204 digitizer for the T10.
  2. Includes the self-extracting executable for train processor version 4.2.0.
        The executable is named P040200.EXE.
        Version PROC4.2.0 06/02/2025
  3. Added cmt-curl configurable consist and maintenance reporting via ftp or sftp.  This is intended to be a universal method for all our units in the future.
  4. Added ZIPTRAIN.BAT to collect trains and configuration files so that Comet can more readily diagnose issues.
  5. To add two new users for SCP, aeiSCP and aeiTransfer, do this:
        A. First extract f.bat, sshd_config, and zip.psp.
           Use the following command from the APU Change prompt:
           shell add-scp-users -o
        B. Next, reboot to add the users.
           Use the following command from the APU Change prompt:
           r,c
  6. The readscale.exe utility takes two arguments, the TRAINNUM.SCA filename, like 00001045.SCA for train number 1045, and the scale configuration file, like CSXSCALE.CFG, and produces the 055 file, in this case 00001045.055.
  7. The installation documents its results in the Maint Report and site notepad.
  8. Restored the original, small simulated train.
  9. Corrected defect in the DP command which prevented EarlyWarning parameters from being displayed under Session1 when the D and Enter keys were pressed.
  10. NTP errors are logged only when the error state changes so they don't fill up the log. A default NTPPARM.DAT file is created if it is missing, preventing some NPT errors.
  11. Renamed the DETECTOR1 process to DETECT1, DETECTOR2 to DETECT2, etc., up to DETECTOR10 to DETECT10, since process names are limited to eight characters.
  12. For I command, Aux 2, #3 now correctly displays the text set up in VIO.CFG.
  13. Session 10 is now accessible.
  14. Parameter loading prints "Old parameter detected", when one is obsolete.

Version 5.3.4.37

  1. Validates MFT files on startup, logging errors to SYS$ERR.LOG and notes.
  2. Fixed two $REMPORT Watchdog issues.
  3. Fixed D,* command to page properly, not one file at a time.
  4. Fixed Watchdog not enabled.
  5. Fixed DIR command causing a crash.
  6. Fixed file delete error when removing old trains.

Version 5.3.4.34

  1. Double Track fixes.
  2. IBackup/IRestore fixes.

Version 5.3.1.1

  1. Ported 5.2.0.17 for Windows 10.
  2. Ported for hardware (COMeT10-3900).
  3. TDA204 Driver replaces RTX.