RailNET T10 Version 5 software
Appearance
Version 5.3.5.6
- Fixes issue where the application would crash when iterating through the train data post-acquisition.
Version 5.3.5.4
- Fixes issue where Default Gateway was not being properly set.
- Fixed issue with SSH tunneling.
- Fixes issues with detector interface.
Version 5.3.5.3
- This file is only meant to upgrade from 5.3.5.2**
- Fixes issue where Default Gateway was not being properly set.
- Fixed issue with SSH tunneling.
Version 5.3.5.2
- Implements the TDA204 digitizer for the T10.
- Includes the self-extracting executable for train processor version 4.2.0.
The executable is named P040200.EXE.
Version PROC4.2.0 06/02/2025- Installation
A. The first step of installation is to extract.
Use the following command from the APU Change prompt:
shell p040200 -o
B. After extraction, simulate a train to force PROCONCE.BAT to run.
Use the following command from the APU Change prompt:
st - Changes
A. Added IOTO010.EXE from TGEN618 for additional I/O fixups.
B. Semaphore files now include:
AXCNVFIX.SEM cancels sequence axle conversion errors.
LLOCOFIX.SEM desensitizes cancellation logic on lead locomotives.
SEQSCALE.SEM assigns scale data to cars in order,
skipping any locomotives at the start.
SSDSCALE.SEM assigns scale data to the cars in order,
skipping any locomotives anywhere.
C. Detects Windows version, running on either XP (LX800) or Windows 10 (T10).
- Installation
- Added cmt-curl configurable consist and maintenance reporting via ftp or sftp. This is intended to be a universal method for all our units in the future.
- Added ZIPTRAIN.BAT to collect trains and configuration files so that Comet can more readily diagnose issues.
- To add two new users for SCP, aeiSCP and aeiTransfer, do this:
A. First extract f.bat, sshd_config, and zip.psp.
Use the following command from the APU Change prompt:
shell add-scp-users -o
B. Next, reboot to add the users.
Use the following command from the APU Change prompt:
r,c - The readscale.exe utility takes two arguments, the TRAINNUM.SCA filename, like 00001045.SCA for train number 1045, and the scale configuration file, like CSXSCALE.CFG, and produces the 055 file, in this case 00001045.055.
- The installation documents its results in the Maint Report and site notepad.
- Restored the original, small simulated train.
- Corrected defect in the DP command which prevented EarlyWarning parameters from being displayed under Session1 when the D and Enter keys were pressed.
- NTP errors are logged only when the error state changes so they don't fill up the log. A default NTPPARM.DAT file is created if it is missing, preventing some NPT errors.
- Renamed the DETECTOR1 process to DETECT1, DETECTOR2 to DETECT2, etc., up to DETECTOR10 to DETECT10, since process names are limited to eight characters.
- For I command, Aux 2, #3 now correctly displays the text set up in VIO.CFG.
- Session 10 is now accessible.
- Parameter loading prints "Old parameter detected", when one is obsolete.
Version 5.3.4.37
- Validates MFT files on startup, logging errors to SYS$ERR.LOG and notes.
- Fixed two $REMPORT Watchdog issues.
- Fixed D,* command to page properly, not one file at a time.
- Fixed Watchdog not enabled.
- Fixed DIR command causing a crash.
- Fixed file delete error when removing old trains.
Version 5.3.4.34
- Double Track fixes.
- IBackup/IRestore fixes.
Version 5.3.1.1
- Ported 5.2.0.17 for Windows 10.
- Ported for hardware (COMeT10-3900).
- TDA204 Driver replaces RTX.