RailNET: Updating the Main Program: Difference between revisions
No edit summary |
No edit summary |
||
| Line 2: | Line 2: | ||
= Overview = | = Overview = | ||
<p>This procedure provides details for authorized personnel to use in updating the software on the RailNet APU-102. Regular updates are required to optimize functionality and resolve known issues.</p> | <p>This procedure provides details for authorized personnel to use in updating the software on the RailNet APU-102. Regular updates are required to optimize functionality and resolve known issues.</p> | ||
<p>Access the files in the Upgrade Files section to update either your RailNet T-10 or LX-800 software | <p>Access the files in the Upgrade Files section to update either your RailNet T-10 or LX-800 software. The T‑10 upgrade requires a three‑file update. The LX‑800 upgrade uses a single package file.</p> | ||
<p>Based on your software, perform the appropriate upgrade procedure using the dedicated section below (T‑10 or LX‑800).</p> | <p>Based on your software, perform the appropriate upgrade procedure using the dedicated section below (T‑10 or LX‑800).</p> | ||
<p>If you have questions or experience an issue during the update process, contact [https://support.cometind.com/support/login Comet Electronics customer support] for assistance.</p> | <p>If you have questions or experience an issue during the update process, contact [https://support.cometind.com/support/login Comet Electronics customer support] for assistance.</p> | ||
| Line 19: | Line 19: | ||
= T-10 Upgrade Procedure = | = T-10 Upgrade Procedure = | ||
Complete the steps below to update the T-10 software | Complete the steps below to update the T-10 software using a three-file update (plus supporting batch file): | ||
::'''IMPORTANT: '''Do not attempt to update via serial port. | ::'''IMPORTANT: '''Do not attempt to update via serial port. | ||
| Line 30: | Line 30: | ||
<li>Review your parameters after reboot, as they may need to be updated.</li> | <li>Review your parameters after reboot, as they may need to be updated.</li> | ||
<li>To verify that the software update was successful, enter the following command: <code>version</code>. | <li>To verify that the software update was successful, enter the following command: <code>version</code>. | ||
<div class="note">'''NOTE: '''This command may take | <div class="note">'''NOTE: '''This command may take a few moments to run.</div></li> | ||
<li>The system displays the version information, as in the example image below. | <li>The system displays the version information, as in the example image below. | ||
<div class="note">'''NOTE:''' | <div class="note">'''NOTE:''' Version details may vary based on the software release.</div></li> | ||
</ol> | </ol> | ||
::[[File:T-10_version_info.png]] | ::[[File:T-10_version_info.png]] | ||
= LX-800 Upgrade Procedure = | = LX-800 Upgrade Procedure = | ||
Complete the steps below to update the LX-800 software | Complete the steps below to update the LX-800 software using a single package file: | ||
::'''IMPORTANT: '''Do not attempt to update via serial port. | ::'''IMPORTANT: '''Do not attempt to update via serial port. | ||
<ol> | <ol> | ||
<li>Connect and login to the APU-102.</li> | <li>Connect and login to the APU-102.</li> | ||
<li>Zrec the | <li>Zrec the file: <code>V5.2.0.17Full.zip</code>. | ||
<div class="note">'''NOTE:''' File names are intended as examples and subject to change based on latest release.</div></li> | <div class="note">'''NOTE:''' File names are intended as examples and subject to change based on latest release.</div></li> | ||
<li>Confirm that the received file is present.</li> | <li>Confirm that the received file is present.</li> | ||
<li>Enter <code>dir ssunzip.exe</code></li> | <li>Enter <code>dir ssunzip.exe</code>.</li> | ||
<li>Enter <code>shell ssunzip V5.2.0.17FULL.zip</code></li> | <li>Enter <code>shell ssunzip V5.2.0.17FULL.zip</code>.</li> | ||
<li>Perform a full system reboot.</li> | <li>Perform a full system reboot.</li> | ||
<li>Review your parameters after reboot, as they may need to be updated.</li> | <li>Review your parameters after reboot, as they may need to be updated.</li> | ||
</ol> | </ol> | ||
Revision as of 19:39, 3 December 2025
NOTE: Some content below previously was published as Comet Electronics Document 480026: Updating Software.
Overview
This procedure provides details for authorized personnel to use in updating the software on the RailNet APU-102. Regular updates are required to optimize functionality and resolve known issues.
Access the files in the Upgrade Files section to update either your RailNet T-10 or LX-800 software. The T‑10 upgrade requires a three‑file update. The LX‑800 upgrade uses a single package file.
Based on your software, perform the appropriate upgrade procedure using the dedicated section below (T‑10 or LX‑800).
If you have questions or experience an issue during the update process, contact Comet Electronics customer support for assistance.
Prerequisites
IMPORTANT: Before updating software on the RailNet APU‑102 (T‑10 or LX‑800), always run the ibackup command to create a mirror of your current configuration. This backup prevents data loss and ensures that your system can be restored if the update process fails.
To confirm that the backup was successful, in the change menu of Session 1, enter \mirror.txt. The backup details are displayed, including the creation date. Verify that the date shown matches the system date of the APU-102. (If the backup date is older than the system date, repeat the process to create a current image.) Optionally, run a parameter dump.
- NOTE: Use the
irestorecommand to restore the original parameters and software version from your backup, if needed.
- NOTE: Use the
See APU102 Auto‑Recovery Quick Start Guide (LX800) for details about creating or updating the backup mirror image for the LX-800 software.
Upgrade Files
Download the appropriate software file:
T-10 Upgrade Procedure
Complete the steps below to update the T-10 software using a three-file update (plus supporting batch file):
- IMPORTANT: Do not attempt to update via serial port.
- Connect and login to the APU-102.
- Zrec the following files:
F.BAT,V53-4-37U,V53-4-37U-List,ZIP.PSP.NOTE: File names are intended as examples and subject to change based on latest release. - Reboot the system to finalize the update.
NOTE: The update is self‑executing; no shell commands are required.
- Review your parameters after reboot, as they may need to be updated.
- To verify that the software update was successful, enter the following command:
version.NOTE: This command may take a few moments to run. - The system displays the version information, as in the example image below.
NOTE: Version details may vary based on the software release.
LX-800 Upgrade Procedure
Complete the steps below to update the LX-800 software using a single package file:
- IMPORTANT: Do not attempt to update via serial port.
- Connect and login to the APU-102.
- Zrec the file:
V5.2.0.17Full.zip.NOTE: File names are intended as examples and subject to change based on latest release. - Confirm that the received file is present.
- Enter
dir ssunzip.exe. - Enter
shell ssunzip V5.2.0.17FULL.zip. - Perform a full system reboot.
- Review your parameters after reboot, as they may need to be updated.