Test Reporting on the Test Bench
When using a LX-800, please make sure the APU-102 software has been updated to V5.2.1.1. or greater, as it comes with CINQ Connect. CINQ Connect does not work independently. Host reporting and report enabling need to be enabled initially, along with inserting the ACC and BAT files for site reporting. The Site Information needs to be configured to match the site settings on RSM, as well.
Current settings for the RV50 show report forwarding to have a IP of 166.165.79.198 and the port set to 23. These are the current config settings in the RV50 and are subject to change.
Login to the APU under the supervisory menu. Using the <ep> command to edit parameters, navigate to to Ports(8), then Ethernet. The parameters need to match what is shown below.

Once set, perform a full reboot using the <r> command. Simulate a train using <st> and, once completed, enter <hr,now> to force reports to be sent immediately. Check the train directory to make sure they’re being reported. After confirming that they have been reported, check RSM for reports to make sure it's going through.