Appendix A - Site Optimization Checklist
Railnet AEI System Site Installation Manual
Site Information
Site Name |
|
Site Number |
|
Track Number |
|
Mile Post |
|
Customer |
|
Job Number |
|
City |
|
State |
|
GPS Coordinates |
N W |
Team Leader |
|
Installers |
|
Site Contact Name |
|
Site Contact Telephone Number |
|
Site Contact E-Mail Address |
|
APU Primary Telephone Number |
|
APU Secondary Telephone Number |
|
APU IP Address |
|
Site Voice Telephone Number |
|
Installation Completion Date |
|
Customer Service Optimization Date |
Other Information
Date phone line(s) installed: __________________
☐ Company (railroad) line
☐ Bell line
Date AC power installed: __________________
System Type
|
|
|
|
|
|
|
|
|
|
|
|
|
Equipment Inventory
Building manufacturer |
|
Serial Number: |
|
|
|
APU serial number: |
|
|
|
|
|
AR2200 Frequency |
|
Serial Number: |
|
Tier |
|
AR2200 Frequency |
|
Serial Number: |
|
Tier |
|
AR2200 Frequency |
|
Serial Number: |
|
Tier |
|
AR2200 Frequency |
|
Serial Number: |
|
Tier |
|
AR2200 Frequency |
|
Serial Number: |
|
Tier |
|
AR2200 Frequency |
|
Serial Number: |
|
Tier |
|
Reno / US Traffic Loop Detector |
VDC |
Serial Number: |
|
|
|
Epic III / Zepic Frequency |
|
Serial Number: |
|
|
|
Antenna Type | |||||
|---|---|---|---|---|---|
|
☐ |
AA3110 Scala Parapanel Antenna 915 MHz |
Serial Number: Serial Number: | ||
|
☐ |
SRL441P Log Periodic |
Serial Number: Serial Number: | ||
|
☐ |
SRL470 Log Periodic |
Serial Number: Serial Number: | ||
|
☐ |
Other |
Specify: | Serial Number: Serial Number: | |
|
☐ |
AI1620 / E4 SmartPass |
Frequency: Frequency: |
Serial Number: Serial Number: | |
|
☐ |
Check Tag AT5720 |
Serial Number: | ||
Check the appropriate item below:
Protector Panel Type:
|
|
|
|
|
|
|
|
Battery Charger Type:
|
|
|
Battery Type:
|
|
|
|
|
|
Wheel Detector Type:
|
|
|
|
|
|
Hut/Enclosure Equipment
Initial each line when completed
_______AC power fail transformer _______Exhaust fan and heater/thermostat
_______Coax cable termination - inside. _______Protection panel checks
_______Door and floor vents open/removed. _______Conduit sealantRailside Equipment
Initial each line when completed
_______Antenna checks. _______Antenna 0 distance to target rail
_______Splice box (waterproofing). _______Antenna 1 distance to target rail
_______Wheel detector mounting checks. _______Coax cable termination - outside
_______Check tag wiring _______
0 = Right 1 = Left Interference Unit Position (Double Track Only)System Equipment Setup and Operational Checks
Initial each line when completed:
_______Loop detector and loop operation
_______(2 Second Delay / 2 Second Extend / Sensitivity 0 - 1 / Mode = Infinite)
_______AC power transformer operation
_______Wheel detector setup, operation
_______TDA-105 setup and operation
_______Wheel detector to antenna offset _______ft. Right or Left
_______SmartPass setup and operation
_______AR2200 RF unit(s) operational tests
_______APU-102(s) operational tests
_______Test double track presence
_______Indicate port used for ITC AUX1PORT.DAT or AUX2PORT. DAT or X-Track (Network)
_______Verify LVD-2000 operation (if equipped)
APU-102 Software Setup and Testing
Initial each line when completed:
_______Initial each line when completed:
_______APU-102 software version ___________
_______Modem card type & serial number:
_______Update site operating parameters
_______Update site session parameters
_______Perform parameters backup
_______Create CF Image
_______Left to right direction: E-W or W-E or N-S or S-N or U-D or D-U
_______Network communications (if applicable)
RF Power Optimization
AVI tier 0 |
Channel 0 |
Channel 1 |
|---|---|---|
RF PWR at source |
||
Reflected power at source |
||
SWR at source |
||
RF PWR at antenna |
||
Reflected power at antenna |
||
SWR at antenna |
||
Horizontal read lobe |
||
Approximate length of run |
||
Coaxial cable type |
||
Attenuation |
||
Check tag operation |
||
DC input to AR2200 |
VDC |
AVI tier 1 |
Channel 0 |
Channel 1 |
|---|---|---|
RF PWR at source |
||
Reflected power at source |
||
SWR at source |
||
RF PWR at antenna |
||
Reflected power at antenna |
||
SWR at antenna |
||
Horizontal read lobe |
||
Approximate length of run |
||
Coaxial cable type |
||
Attenuation |
||
Check tag operation |
||
DC input to AR2200 |
VDC |
AVI tier 0 |
Channel 0 |
Channel 1 |
|---|---|---|
RF PWR at source |
||
Reflected power at source |
||
SWR at source |
||
RF PWR at antenna |
||
Reflected power at antenna |
||
SWR at antenna |
||
Horizontal read lobe |
||
Approximate length of run |
||
Coaxial cable type |
||
Attenuation |
||
Check tag operation |
||
DC input to AR2200 |
VDC |
Site Drawing
Sketch site layout below and include the following:
1) All tracks in immediate area.
2) Direction arrow showing North.
3) Any buildings, metal fences in front of or behind antennas.
4) Overhead high voltage power lines.
5) Transducer location.