Jump to content

Frauscher Wheel Detector Installation with Web Bolt Kit

From DocDepot
Revision as of 19:49, 27 February 2025 by GMalcom (talk | contribs) (Created page with "The following details installation and optimization of the Frauscher RSR110, dual segment wheel detector (aka. wheel sensor), utilizing the Rail Web Bolt kit. <br>'''Site Considerations: ''' *The RSR110 wheel sensor must be mounted on the inside face of rail (wheel flange side), between ties (crib). Wheel sensor mounting utilizes the appropriate Rail Web Bolt Kit. *Different bolt kits are applicable to different gauge of rail. If upgrading from Tiefenbach wheel sensor,...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)

The following details installation and optimization of the Frauscher RSR110, dual segment wheel detector (aka. wheel sensor), utilizing the Rail Web Bolt kit.


Site Considerations:

  • The RSR110 wheel sensor must be mounted on the inside face of rail (wheel flange side), between ties (crib). Wheel sensor mounting utilizes the appropriate Rail Web Bolt Kit.
  • Different bolt kits are applicable to different gauge of rail. If upgrading from Tiefenbach wheel sensor, the Frauscher installation utilizes the same mounting holes. Skip section 2.1 on drilling the rail.
  • If mounting on a curve, the wheel sensor should be mounted on the rail which shows less lateral wear of head of rail. This is usually the inside rail.
  • Ensure when mounted that the housing edge of the wheel sensor does not touch the head of rail. (see Section 2.3)
  • 2’ (600mm) minimum distance from rail joints (including welded joints).
  • 10” (250mm) minimum distance from guard rails or other route’s rail/frog, etc., if mounted in a switch.
  • 2’ (600mm) minimum distance from another Frauscher on the same rail.
  • 3’ (1 meter) minimum distance from other manufacturer’s wheel detectors.
  • 20” (500mm) minimum from ANY movable metal object

Requirements: 

  • The APU-102 must have a TDA204, Track Directional Analyzer card, strapped for Frauscher Wheel detector.
  • Minimum AEI software version 5.2.0.6+

Parts Required:

  • 400220, Frauscher Dual Segment Wheel Detector
  • 400244, Frauscher Rail Web Bolt Kit, EXC10
  • 400245, Frauscher Rail Web Bolt Kit, EXC10/21
  • 400227, 5 Meter cable Assembly
  • 400222, 10 Meter cable Assembly
  • 400228, 25 Meter cable Assembly

Tools Required:

  • 17mm 6-point socket
  • 19mm 6-point socket
  • Ratchet handle (drive to fit sockets above)
  • Torque wrench (drive to fit sockets above), minimum torque range from 15 to 40 Nm (about 10-30 ft/lb)
  • 6 mm hex key (Allen wrench)
  • Combination square or string and tape measure (metric preferred)
  • Shovel
  • Pick
  • Rake
  • Hammer
  • Misc. small hand tools.
  • Laptop PC with terminal emulation program (or someone with remote access to the APU)
  • Null modem Cable to Local Port (or connect via network if available)
  • Digital Voltmeter
  • Angle Grinder

Optional Tools Required: 

Mounting the Frauscher Wheel Sensor 

Drill the rail 

1. Determine mounting location as outlined above. The crib chosen should be in line with the RFID antennas.

2. Clear the ballast from the crib, 4-6 inches below the foot of the rail.

3. Remove creeper clip(s) if necessary.

4. Trench for cable from the crib back to the track-side junction box or wiring pedestal. Usually “scratched” in, but follow your railroad’s standard practices.

5. Examine the rail web where the sensor will be mounted. If there is any raised lettering on the rail, grind flush to the rail web surface. (both sides of rail)

6. Refer to drawing 101-0008-00 as needed for steps that follow.

7. Secure and level the rail mounting template and tighten setscrew.

8. Insert the center punch into each hole and mark the rail by striking the center punch.

9. Remove template and drill two pilot holes (approximately 1/8” diameter and 1/8” deep) where marked to serve as a guide.

10. Using a rail mounted drill, drill two 17/32” (13mm) mounting holes, using the pilot holes as alignment guide.

11. Clear shavings and drill lubricant/coolant.

Mounting the Sensor to the Rail 

If replacing a Tiefenbach, disconnect power from the TDA105 and remove the Tiefenbach from the rail. Examine the rail web where the sensor bolts will seat. If there is any raised lettering on the rail where the mounting bolts and nuts will seat, grind flush to the rail web surface. (both sides of rail) 

Bolt kit EXC10 should work for most North American rail gauges. If measurement “B” is excessive after mounting, it will be necessary to change to bolt kit EXC10/21. Refer to Figure 3 below for “A” and “B” measurements.

1. Align the eccentric bolt kits as shown in Figure 1 for the 0° position and mount the bolt kits to the sensor (top of sensor facing up). Ensure the spring washer is installed correctly as shown in Figure 2. The 0° position is for proper vertical alignment (measurement “A”) on freshly drilled rail. Bolts can be rotated if necessary for rail wear. Refer to chart 1.

2. Leave loose enough for minor adjustment when attaching to the rail.

Figure 1

Ensure that the conical spring washers are in the correct position (top surfaces must face outwards towards the locknuts). 
Figure 2

3. Mount the sensor to the rail and secure with spring washer and locknut. Ensure the spring washer is installed correctly as shown in Figure 2. Snug up all mounting locknuts and check vertical and horizontal measurements are correct. If adjustments are required, refer to the appropriate section(s) below.

NOTE
     When mounted, the sensor must not touch the rail head.

Measurement “A” is from the top if the rail to the highest point of the top of the sensor.

Measurement “A” can be checked with a combination square. Alternate method; span the gauge with a weighted string and measure from string to highest point of sensor.

It must be between 40‐45mm (1 9/16 to 1 25/32 inches)


Measurement “B” is from the inner surface of the
wheel sensor to the outside of the railhead.

It must be between 0‐6mm (0 to 1/4 inch)

Measurement "A" and "B"
Figure 3

Sensor Adjustment

Tighten rail mounting and sensor mounting nuts snugly. Verify both “A” and “B” measurements are correct. See Figure 3. If within specification, torque rail mounting nuts to 29.5 ft/lbs (40Nm) and the sensor mounting nuts to 11 ft/lbs (15Nm). 

If vertical adjustment is necessary, note the current “A” measurement. Remove the sensor from the rail. For height (“A” measurement), the eccentric bolts can be rotated per chart 1. Refer to Figure 1 for rotation.