Jump to content

Obtaining Diagnostic Train Records

From DocDepot

Accurate diagnostic train records are essential for understanding equipment performance, identifying defects, and ensuring accountability in service and maintenance. These records provide a clear history of system behavior, allowing us to verify issues and track patterns.

  1. Connect (Telnet) into Comet RailNET AEI Reader
  2. You will see 4 sessions.
      1. To enter the front door, select session 1.
  3. Enter the supervisory password: (Default:super)
  4. Type in your initials as this will log the event of you getting in, in the system report(can be used for diagnostics).
  5. To look at the recorded train data, Type "D" and then enter. It will show you each Train Log or Consist.
      1. It is only going to show you the most recent. If you would like to see more Trains/Consists, type "D,*" and then using "C" for continuous to see more in the directory. 
  6. If you would like to see how the wheel sensor or antennas(RFID system) is reporting, you can type “DDS” this stands for Data Dump Summary.
  7. DDF plus sequence number will give you the direction, tag information, and direction.
  8. DDT plus the sequence number will give you the tags. 

Any other needs can be simply found by typing "?" and enter, hit c for continuous to show more commands available to you.