400194
Appearance
Special:Whatlinkshere/400194
Low Voltage Detector LVD-2000
General
DC power distribution for battery powered AEI sites which includes advanced battery monitoring, low DC warning notification and battery drain protection.
Features
Low Battery Voltage Detection
- Continuously monitors battery voltage. When warning voltage level is reached it sends signal to APU. A “Low Battery Voltage“ maintenance message will be sent to your maintenance host. A complimentary maintenance message will be sent when voltage is restored.
- Status indicator.
- Test button to simulate low battery input at warning level.
Battery Load Cutout
- Will disconnect all loads from battery when cutoff voltage level is reached to prevent excess battery drain and resulting damage to batteries.
Automatically re-establish load connections when battery charger voltage is restored.
- Status indicator
- Test button to simulate low battery input at cutoff level.
DC Power Distribution
- Simplified DC distribution wiring.
- Fused power outputs for standard site configurations (up to 3 APU’s and their auxiliary devices)
- Fused Auxiliary DC outputs are switchable by command on APU. Can be used to reset loop detectors, TDA105’s, SmartPasses, etc.
- Output power status indicators.
Additional Features
- All DC outputs protected by resettable fuses.
- All solid state components for increased reliability.
- Uses connections similar to ones already in use.
- Available for 12 or 24 volt systems.