Fitting, Field Installable, Type N for 1/2" Coaxial cable;

General

Type N Female Positive Stop™ for 1/2 in AL4RPV-50, LDF4-50A, HL4RPV-50 cable.

400261
400261

Specifications

Body Style Straight
Cable Family AL4-50
Harmonized System (HS) Code 85366910 (Coaxial cable and other coaxial electric conductors)
Inner Contact Attachment Method Captivated
Inner Contact Plating Silver
Interface N Female
Mounting Angle Straight
Outer Contact Attachment Method Ring-flare
Outer Contact Plating Trimetal

Dimensions

Length 2.900 in
Diameter 0.880 in
Nominal Size 1/2 in
Weight 0.195lbs

Environmental

Operating Temperature -55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature -55 °C to +85 °C (-67 °F to +185 °F)
Corrosion Test Method MIL-STD-1344A, Method 1001.1, Test Condition A
Immersion Depth<button class="tooltip" type="button" data-toggle="tooltip" data-placement="top" data-original-title="Immersion at specified depth for 24 hours"></button> 1 m
Immersion Test Mating Unmated
Immersion Test Method IEC 60529:2001, IP68
Moisture Resistance Test Method MIL-STD-202F, Method 106F
Thermal Shock Test Method MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C
Vibration Test Method IEC 60068-2-6
Water Jetting Test Mating Unmated
Water Jetting Test Method IEC 60529:2001, IP66