<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://docdepot.railrsm.com/index.php?action=history&amp;feed=atom&amp;title=Resistance_ARC_Welding_in_Proximity_to_AEI_Equipment</id>
	<title>Resistance ARC Welding in Proximity to AEI Equipment - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://docdepot.railrsm.com/index.php?action=history&amp;feed=atom&amp;title=Resistance_ARC_Welding_in_Proximity_to_AEI_Equipment"/>
	<link rel="alternate" type="text/html" href="https://docdepot.railrsm.com/index.php?title=Resistance_ARC_Welding_in_Proximity_to_AEI_Equipment&amp;action=history"/>
	<updated>2026-07-14T03:22:15Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.0</generator>
	<entry>
		<id>https://docdepot.railrsm.com/index.php?title=Resistance_ARC_Welding_in_Proximity_to_AEI_Equipment&amp;diff=2480&amp;oldid=prev</id>
		<title>DGast at 18:12, 4 June 2026</title>
		<link rel="alternate" type="text/html" href="https://docdepot.railrsm.com/index.php?title=Resistance_ARC_Welding_in_Proximity_to_AEI_Equipment&amp;diff=2480&amp;oldid=prev"/>
		<updated>2026-06-04T18:12:30Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 18:12, 4 June 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Resistance ARC welding on or near the rail presents electrical and thermal hazards to AEI equipment and associated wiring. Comet Electronics&amp;#039; position on welding operations in the vicinity of AEI installations is as follows:&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Resistance ARC welding on or near the rail presents electrical and thermal hazards to AEI equipment and associated wiring. Comet Electronics&amp;#039; position on welding operations in the vicinity of AEI installations is as follows:&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Where &lt;/del&gt;AEI equipment &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;is integrated with a track circuit, &lt;/del&gt;the &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;track circuit &lt;/del&gt;must &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;be disconnected and electrically isolated prior &lt;/del&gt;to any &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;welding activity on &lt;/del&gt;the &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;rail. Work should not commence until isolation is confirmed&lt;/del&gt;.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;=== General ===&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;All &lt;/ins&gt;AEI equipment &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;and associated wiring must be positioned outside the spark zone established for &lt;/ins&gt;the &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;welding operation. Personnel &lt;/ins&gt;must &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;take precautions &lt;/ins&gt;to &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;ensure that spatter, hot metal fragments, or slag do not contact equipment housings, cable runs, connectors, or &lt;/ins&gt;any &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;other wiring associated with &lt;/ins&gt;the &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;AEI installation&lt;/ins&gt;.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;All &lt;/del&gt;AEI equipment &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;and associated wiring &lt;/del&gt;must be &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;positioned outside &lt;/del&gt;the &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;spark zone established for &lt;/del&gt;the &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;welding operation&lt;/del&gt;. &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Personnel must take precautions to ensure that spatter, hot metal fragments, or slag do &lt;/del&gt;not &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;contact equipment housings, cable runs, connectors, or any other wiring associated with the AEI installation&lt;/del&gt;.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;=== Track Circuit ===&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Where &lt;/ins&gt;AEI equipment &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;is integrated with a track circuit, the track circuit &lt;/ins&gt;must be &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;disconnected and electrically isolated prior to any welding activity on &lt;/ins&gt;the &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;rail in proximity of &lt;/ins&gt;the &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;AEI site&lt;/ins&gt;. &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Work should &lt;/ins&gt;not &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;commence until isolation is confirmed.  Proximity is defined as less than 30 ft from track circuit connection&lt;/ins&gt;.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;These requirements apply regardless of welding duration or perceived proximity.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;These requirements apply regardless of welding duration or perceived proximity.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>DGast</name></author>
	</entry>
	<entry>
		<id>https://docdepot.railrsm.com/index.php?title=Resistance_ARC_Welding_in_Proximity_to_AEI_Equipment&amp;diff=2479&amp;oldid=prev</id>
		<title>DGast: Created page with &quot;Resistance ARC welding on or near the rail presents electrical and thermal hazards to AEI equipment and associated wiring. Comet Electronics&#039; position on welding operations in the vicinity of AEI installations is as follows:  Where AEI equipment is integrated with a track circuit, the track circuit must be disconnected and electrically isolated prior to any welding activity on the rail. Work should not commence until isolation is confirmed.  All AEI equipment and associa...&quot;</title>
		<link rel="alternate" type="text/html" href="https://docdepot.railrsm.com/index.php?title=Resistance_ARC_Welding_in_Proximity_to_AEI_Equipment&amp;diff=2479&amp;oldid=prev"/>
		<updated>2026-06-04T18:07:39Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;Resistance ARC welding on or near the rail presents electrical and thermal hazards to AEI equipment and associated wiring. Comet Electronics&amp;#039; position on welding operations in the vicinity of AEI installations is as follows:  Where AEI equipment is integrated with a track circuit, the track circuit must be disconnected and electrically isolated prior to any welding activity on the rail. Work should not commence until isolation is confirmed.  All AEI equipment and associa...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;Resistance ARC welding on or near the rail presents electrical and thermal hazards to AEI equipment and associated wiring. Comet Electronics&amp;#039; position on welding operations in the vicinity of AEI installations is as follows:&lt;br /&gt;
&lt;br /&gt;
Where AEI equipment is integrated with a track circuit, the track circuit must be disconnected and electrically isolated prior to any welding activity on the rail. Work should not commence until isolation is confirmed.&lt;br /&gt;
&lt;br /&gt;
All AEI equipment and associated wiring must be positioned outside the spark zone established for the welding operation. Personnel must take precautions to ensure that spatter, hot metal fragments, or slag do not contact equipment housings, cable runs, connectors, or any other wiring associated with the AEI installation.&lt;br /&gt;
&lt;br /&gt;
These requirements apply regardless of welding duration or perceived proximity.&lt;/div&gt;</summary>